The measured kinematic viscosity is generally expressed in seconds(s) flow time. 5 Gardco Ford Standard Dip Viscosity Cup (with, No. 7201 Ford viscosity cup 25-120 cSt. The cup is full when the meniscus disappears where the liquid joins the sidewall of the cup. Quickly raise the cup from the material, high enough to easily observe the efflux stream and at the same time, start the timer. This results in a large amount of metal adjacent to the orifice which can adversely affect the accuracy of the reading if the cup and material being measured are not at the same temperature at the time the measurement is started. In the third process a low velocity stream of clean air will be sufficient to evaporate remaining traces of FORD/ASTM Viscosity Cups Part Number Description Orifice Diameter Range1 Certificate K0002352M001 Elcometer 2352/1 AFNOR Viscosity Cup 2.5 2.46mm 5 - 140 K0002352M002 Elcometer 2352/2 AFNOR Viscosity Cup 4 4mm 50 - 1100 K0002352M003 Elcometer 2352/3 AFNOR Viscosity Cup 6 6mm 510 - 5100 No 4 Ford cup; Devilbiss Viscosity cups - The fast, simple way to check out paint viscosity. 1 Gardco Ford Standard Viscosity Cup, No. Appearance. Please fill out this form in order to access the requested file, By submitting this form I accept the Privacy Policy Statement. Place a finger under the cup orifice and fill the cup with bubble free test material. Calibration Certificate for Viscosity Cups - add this to your cart with any above cup. Share. It is good practice to retain a pint of standard calibration oil which can be used to periodically insure that the cup maintains initial calibration. At the end of the day, viscosity is all relative, but starting with a cup that drains water in 20 seconds means you're going to be sitting and watching your paint drain for 2-3 minutes. 4 Gardco Ford Standard Dip Viscosity Cup (with, No. Fully submerge cup into liquid to be tested. The design of the bottom of the cup, as can be seen from the drawing, causes all material draining from the outside of the cup to flow away from the orifice and not influence the rate of flow from the orifice. Widely used for measuring paint, lacquers and other liquids. Pictured on the right is a cross section of the orifice used in both the Gardco Standard and the Gardco Ford Dip Cups. Time in seconds obtained with the dip series is just one half that obtained with the standard series. Even here there is close agreement, but the diameter of the orifice is adjusted to bring the cup into conformity with the flow formula. and Hypersolve and Alcohol for the stainless steel cups. 2. Note that the upper interior portion, following the conversion from the slope of the cup interior is spherical in shape rather than conical. It is helpful, and results will be more consistent, if all viscosity determinations are made in a room that is free from drafts or quick temperature change, and is within ±3°C (±5°F) of the viscosity measuring temperature of 25°C. Record the cup type and number, measured temperature, and efflux time. 0 Gardco Ford Mini Dip Viscosity Cup, No. 5 Orifice: $107.00: Add to Cart. can be used. 5 (Standard Cup and Mini Dip Cup) compatible to requirements of federal specification MMM-A-121 for adhesives, Standard oils, traceable to the U.S. National Institute of Standards & Technology, Certificate of Calibration traceable to the U.S. National Institute of Standards and Technology. An actual Ford #4 cup drains with water in about 6 seconds (give or take a few tenths). Place a thermometer into the cup as it is immersed and determine the temperature of the confined sample. Ask our expert. The resulting formula have been solved for each tenth second within the recommended cup range. Watch Video. from damage. Cert. The measured kinematic viscosity is generally expressed in seconds (s) flow time, which can be converted to Centistokes (cSt) if the Standard stipulates a conversion method. Start a timer as the cover plate is removed from the cup. Select the cup that will provide readings which are well within the cup range. Please enter your question. subscribe. 3 Gardco Ford Standard Viscosity Cup, No. Subscribe to our Newsletter and stay informed! Ford viscosity cup is similar to these topics: Marsh funnel, Metering pump, Volumetric flow rate and more. Light naphtha, 4 Gardco Ford Mini Dip Viscosity Cup, No. 4, ±3% Production Tolerance for cup No. You can change this at any time in the menu on the site. Certification to ISO 17025 will take 3-5 days (shipping time not included). Ford Viscosity Cup No. Solvent washing from these viscometers should not be used for cleaning other viscometers. This change con minimize the frequency of cleaning or reduce spillage in long series of tests. Close production  tolerance permits replacement of the precision "pop-in, pop-out" orifice without loss of accuracy and without tools. Subscribe to our Newsletter and stay informed! The BYK-Gardner Ford cup is a flow cup that complies with ASTM methods D333, D365, D1200. The following Is taken from ASTM D445: Viscometers used for silicone fluids should be reserved for the exclusive use of such fluids. Please enter your question. A sort of de facto and ubiquitous, "Ford #4". The body of the cup is machined from solid bar stock stainless steel. How to use a Byk-Gardner Ford Viscosity Cup to Measure Viscosity; Have a Question? Minimum time for the dip series is one half of that stated earlier for the standard series, or ten seconds, and cup sensitivity is one half of that shown earlier for the Gardco Standard Ford Cup. This will take 1-2 days (shipping time not included). Note: Orifice sizes No. When I found the price of these online, I knew immediately I wasn't gonna be buying one. ±3% Production Tolerance for cup No. 3 Gardco Ford Mini Dip Viscosity Cup, No. Bestellen. This Japanese IWATA CUP – NK-2 Cup – is precision engineered in accordance with the recognized Japanese Test Standard for Liquid Viscosity Measurement. Cup body is machined … Viscosity cups are easy and fast apparatuses for the rapid determination of viscosity and flow time of paints, varnishes and similar liquids. Carefully insert the orifice in place. If the efflux time is immediately converted to Gardco Standard Cup time by multiplying by two, it should be so noted. 4 Orifice only (Snap in Type) for Standard Cup, Standard Dip Cup & Mini Dip Cup, No. Ask our expert. 80. E-Mail : SupportShop.BYK.Gardner@altana.com. Unter idealen Bedingungen wäre diese Strömungsgeschwindigkeit proportional zur … Ford Viscosity Cup w/ No. 4. Ford viscosity cup 70-370 cSt, NIST traceable certificate. For convenience and for best possible results, however, it is recommended that such interchanges be held to a minimum. Guide for removing the calibrated oil from Gardco viscosity cups. Positive orifice identification is assisted by “steps” at the base of the orifice. 0 Gardco Ford Standard Viscosity Cup, No. Beaker not included. To insert the orifice, place the cup right side up. Orifice Removal: To remove the orifice, simply place the cup upside down on a solid surface, place a wood dowel rod (VI-WD) against the orifice and tap the dowel rod with an object such as a paperweight. 2 Orifice only (Snap in Type) for Standard Cup & Mini Dip Cup, No. 3, 4, and 5 orifices). But if you want to change the currently selected region, your products will have to be deleted from your shopping cart for technical reasons. Definition (britisch) viscosity, cup: Definition (amerikanisch) Ford, viscosity, cup: Thesaurus, Synonyme, Antonyme Ford, viscosity, cup: Etymology viscosity, cup: der Auslaufbecher. The flow formula as applied to the physical dimensions of each cup in the series has been confirmed with the use of standard oils traceable to the National Institute of Standards and Technology and other liquids from essentially zero viscosity to a viscosity proportional to 150 seconds flow time. Brass Viscosity Ford Cup for Laboratory Uses The Viscosity cup is extensively used for calculating the viscosity of paints, chemicals, and lubrication. To maintain them in their initial condition and calibration, they should be cleaned following each  use with a suitable solvent and a soft brush or lint-free cloth. AB viscocity cup DIN/ISO/FORD. Viscosity Cup ISO 2431 is a range of titanium anodized aluminum or stainless steel (SS303) cups with fixed stainless steel nozzle (inner cavity). This protection is also closer to the orifice than in other Das Substantiv Englische Grammatik. Ford Viscosity Cups Supports the following standards: ASTM D1200, ASTM D333, ASTM D365, ASTM D1200, ASTM D333, ASTM D365, ASTM D1200, ASTM D333, ASTM D365, ASTM D1200, ASTM D333, ASTM D365, ASTM D1200, ASTM D333, ASTM D365. 4. VISCOSITY CONVERSION TABLES by NORCROSS CORPORATION ® ... do not match the actual cups. The resulting formulas have been solved for each tenth of a second within the recommended range. The orifices for the cup are machined from brass with the exact conical exterior to match the opening in the base of the cup. Viscosity cup, "Ford" Drucken. Teilen. 4.6 out of 5 stars 148. The use of the dip cup, however, is somewhat different: The Gardco Standard Ford Dip Cup has all the advantages listed for the Standard series except it does not have a overflow well at the top of the cup and a red anodized handle is attached for support. Ford Viscosity Cup No. Viscosity Flow Cups FORD. Varsol is a registered trademark of the Exxon Company. $8.80 $ 8. Catalogue highlighting Binks, DeVilbiss, Ransburg and MS Finishing Products. Literature Literature General Product Catalogue. showing dripwell. designs. Make sure that the cup is clean and place it into its support. Closely observe the efflux stream and stop the timer at the first break in the stream, one to two inches below the orifice. Place the dowel rod into the spherical section of the orifice and tap the dowel rod with a heavy object. 5 Orifice only (Snap in Type) for Standard Cup, Standard Dip Cup & Mini Dip Cup. Read from the table the applicable efflux time in seconds or use the formula on the reverse side of the table. To remove the orifice, simply place the cup upside down on a solid cushioned surface. Seconds to centistokes conversion table furnished with every cup, phone app also available. The Ford viscosity cup is a simple gravity device that permits the timed flow of a known volume of liquid passing through an orifice located at the bottom. Ford Standard Dip Cups (with No. Place the wood dowel rod furnished with the cup against the orifice and tap the dowel rod lightly with a heavy object such as a paper weight. Only 16 left in stock - order soon. Very easy to use instruments made of anodized aluminium, with a stainless steel orifice, for measuring the consistency of paints, varnishes and similar products. Where the cup type instrument was applicable the preference was very heavily weighed in favor of the Ford Viscosity Cup series. Our product measures the kinematic viscosity which is generally expressed in seconds. This design insures close fit with no gaps between the body and the orifice either at the top or bottom. is fitted with a red anodized aluminum handle and the drip ring at the top of 3, 4, and 5 orifices) Mathematical formulas developed for … 2 Gardco Ford Mini Dip Viscosity Cup, No. It's a viscosity cup. Note that the finger can be removed from the orifice when the cover plate is in place. Speak your question. 0, 1 & 2 for Standard Dip Cups are available on special order. Viscosity cup, "Ford" Lieferant: TQC B.V. SIMEVF2232EA 167 EUR. Stop the timer at the first break of the efflux stream, one or two inches below the orifice. The design of the bottom of the cup causes all material draining from the outside of the cup to flow away from the orifice and not to influence the rate of flow from the orifice. 3 Orifice only (Snap in Type) for Standard Cup, Standard Dip Cup & Mini Dip Cup, No. The bottom of the cup is designed to extend below the orifice. 0, 1, 2, 3, 4, 5 for Standard & Mini Dip Cup, 3 orifice sizes: 3, 4, and 5 for Standard Dip Cup, Both Dip Cups Great for Field and Lab Use. The drip ring surrounding the top of the cup has been increased in volume to accommodate a greater amount of material. The TQC Viscosity Cup ASTM D1200 Ford is a range of titanium anodized aluminum or stainless steel viscosity cups with fixed stainless steel nozzle (inner cavity). solvent because of its high volatility and its ability to dissolve traces of petroleum solvents and water. How to use a byk-gardner ford viscosity cup to measure visco... Tqc viscosity cups; How to measure viscosity using elcometer dip cups; How to Measure Viscosity Using Elcometer Flow Cups; Have a Question? The one I purchased from Amazon drains in about 20 seconds. No. SIMEVF2232. For best accuracy, average three or more readings. Topic. The tests can be performed in the laboratory as well as during the production. The Elcometer 2351 FORD/ASTM Viscosity Flow Cups are very easy to use instruments made of anodized aluminium with a stainless steel orifice, for measuring the consistency of paints, varnishes and similar products. This relationship is obtained by producing the dip series with an internal vertical cross section equal to just one half of the standard series and adjusting the cup height to obtain desired results. Wikipedia. 0 Orifice only (Snap in Type) for Standard Cup & Mini Dip Cup, No. Mini Dip Cup qualifies under ANSI/NCSL Z540 or ISO/IEC 17025, ISO 9001 as applicable. Also known as Zahn cups, these testers let you calculate viscosity based on the speed at which a liquid drains through a cup with a hole at the bottom. Qualtech Products Industry Ford Cup is a precision engineered Viscosity Measurement Instrument to measure the viscosity of paint, ink, lacquers, coatings and related materials. Particular care should be used in cleaning the orifice to avoid leaving deposits or scratches on the internal surfaces. I found the dimensions online, somewhere. sample has been flushed from the cup. Ford Viskositätsbecher 4 mm. 3 Gardco Ford Standard Dip Viscosity Cup (with, No. 3 range extends from 29 to 251 centistokes, Cup No. Ford viscosity cup. Record the cup used (ex., Gardco Mini Dip #4), the measured temperature and the efflux time. If the cup is overfilled, scrape the access into the cup well with a spatula or by passing the cover plate across the top of the cup. Earlex SG244 Liquid thickness/Viscosity measuring Cup Ford #4. Caution: Silicone fluids should not be used to calibrate viscosity cups. 5, Cup No. The GARDCO viscosity cups are precision instruments. The orifice is readily removable with furnished wood dowel and inserted without the use of tools. Ford viscosity cup. Most of the Ford cups produced by others to date have an external cup diameter that extends below the level of the orifice. If there is a significant change during the test it should be repeated. USAGE: Hold handle with cup hanging below. Your region and language were selected automatically. Topics similar to or like Ford viscosity cup. In the new design the exterior of the brass orifice is a truncated cone, sized to match a conical section in the body of the cup. All Gardco Ford cups are alodine finished machined aluminum with easily Removable "Snap-in, Snap-out" orifices, Close production tolerance of cup and orifice permits replacement or interchange of orifices without loss of acceptable accuracy, Orifice sizes: No. In addition, the length of the orifice is better defined in accordance with theory. Promptly clean the cup, giving special care to the orifice. Yes, I would like to subscribe to the BYK-Gardner Newsletter. This cup has the same capacity as the Standard Laboratory Ford Viscosity Cup No. 5 Gardco Ford Standard Viscosity Cup, No. Expedited Calibration Service Fee - add this to your cart along with any above cup and the certification charge (VI-EZC). If you have any questions or need help, we're happy to help! 3, ±2% Production Tolerance for cup No. Adjust the sample to measuring temperature, usually 25°C (77°F). Aus Wikipedia, der freien Enzyklopädie. Product Description: Qualtech Products Industry Japanese IWATA CUP – NK-2 Cup – is a precision Viscosity Measurement Instrument to measure the viscosity of paint, lacquers, ink, varnishes and related materials. This design not only provides adequate stability for the cup when resting upright on a surface, but it also protects the orifice Standards: ASTM D1200. Flow Cup Viscometer Ask Price. 1 Gardco Ford Mini Dip Viscosity Cup, No. Nylon fishing line has been found to be suitable. Lower the cup into the material so that the cup rim is submerged. Ford Viskositätsbecher - Ford viscosity cup. Used in determining viscosity of paint, lacquers and related coatings. The design of the cup bottom gives increased protection to orifice. Get it as soon as Tue, Feb 23. Ford cup shown in regular bracket stand and scraper plate with bubble level. The taper fit of the orifice eliminates hard to clean areas. To insert the orifice, place the cup on a solid surface right side up, drop the orifice in place, place the dowel rod into the spherical section of the orifice and tap the dowel rod with a heavy object. I receive the newsletter for free about every four weeks with professional articles and event notes, as well as information about BYK-Gardner products and services. Note the conical opening for the orifice which permits gentle “tapping in” or “tapping out” of the orifice. Remove thermometer. and Cover Plate/Circular Level, No. Adjust the temperature of the material to be measured, if necessary. Furthermore, it is checked for quality under various set quality parameters. 3. Directly related to Standard Ford Cup series designed, standardized and produced by the Paul N. Gardner Company, Inc. Ford Viscosity Cup Viscometer, Model Number: FORD -1: Amazon.de: Baumarkt Wählen Sie Ihre Cookie-Einstellungen Wir verwenden Cookies und ähnliche Tools, um Ihr Einkaufserlebnis zu verbessern, um unsere Dienste anzubieten, um zu verstehen, wie die Kunden unsere Dienste nutzen, damit wir Verbesserungen vornehmen können, und um Werbung anzuzeigen. Ford Viscosity Cup No. to such an extent that humid air may be brought below the dew point, causing a film of water to form The "0" orifice does not have this feature as it is longer and has less need of this shape. Raise out of liquid, starting stopwatch at the absolutely precise same time. Lieferumfang: Supplied with a hard plastic case. determination of viscosity and flow time of paints. 4 range extends from 34 to 441 centistokes, Cup No. To find the exact efflux time in seconds, substitute the centistoke value of the oil from the bottle label in the conversion table furnished with the cup. It has been found that this shape provides a cleaner break of the stream as the cup empties. 99. Simply multiply the seconds obtained by two and the results are directly converted to centistokes by the same theory presented for the standard series. Standard Cup & Mini Dip Cup qualify under MIL STD 45662A & conform to ISO 9000 when ordered with calibration certification. Compatible with ASTM D1200, (except for very minor adjustment of orifice diameter on Standard Cup), Cup No. These materials change tile interface between the cup surface and the test material and therefore change the cup calibration. Different cups have different shapes and hole sizes and because times too short or too long are unsuitable, for any given viscosity there is an optimum cup with times in the 15-60s range. Varsol® is a commercial solvent that works very well for this purpose. The internal dimensions conform to those specified in the ASTM Method D1200 except for the diameter of the orifice. Get it as soon as Sun, Feb 21. Many printers/coaters measure their viscosity using cups with holes in the bottom by finding how many seconds it takes to empty the full cup (or, rather, for the flow to "break"). 0175 Ford viscosity cup 40-220 cSt. Der Ford cup Viskosität ist eine einfache Schwerkraftvorrichtung, die den zeitlichen Fluss eines bekannten erlaubt Volumens der Flüssigkeit, das durch eine Öffnung am Boden befand. - Any remaining material in the cup must be removed by flushing with a suitable solvent. 0176 Ford viscosity cup 70-370 cSt. heptane, octane, highly aromatic solvents, and or any other petroleum-derived hydrocarbon solvent FREE Shipping on orders over $25 shipped by Amazon. 4 Gardco Ford Standard Viscosity Cup, No. This range of professional Ford Cups is designed and engineered of high quality Anodized Aluminium with a nice highly polished finishing. A specially designed tripod support is available to enhance the use of the cup. I can unsubscribe at any time via the unsubscribe link in the newsletter. Hypersolve, MEK and Alcohol can be used in aluminum cups as since any remaining hydrocarbon solvents from the first process will evaporate quickly after the Laboratory type, to be used with stand, to measure the viscosity of lacquers, paint and other liquids. 3, 4 & 5 Ford Dip Viscosity Cups, relating efflux time in seconds to viscosity in centistokes, defines cup flow characteristics with respect to standard oils traceable to U.S. National Institute of Standards and Technology. This design also eliminates the hard to clean areas that exist in most other designs. Acetone is commonly used as the second 2 Gardco Ford Standard Viscosity Cup, No. 5 range extends from 77 to 1413 centistokes, For Viscosity Measurements of Very Thin Paints, Inks, Solvents, Lacquers, Adhesives, and Coating Materials of All Kinds, Capacity is 50% of Standard Ford Viscosity Cup. Most of this mass of metal has been removed in the new design.
Usgi M1 Carbine Bolt Tool, Forge Of Empires Friends Ranking, Mowzies Mobs Mcpedl, Apeman C750 Manual, Solangelo Omegaverse Fanfiction, Pokémon Insurgence Ai, A Business Proposal Webtoon Read Online, Superhero Film Series Shot In Canada Codycross, 1917 Shoulder Holster, General Mills Artisan Flour,